You are here:

I8-M700 Medical Incinerator

The i8-M700 stands as the second largest model in our medical incinerator range, engineered specifically to outperform any competitor in its class. This high-capacity medical waste incinerator delivers exceptional size, performance, and scalability to accommodate expanding waste streams, capable of burning up to 300kg of waste per hour.

Proven reliable in diverse and demanding environments worldwide, the i8-M700 serves as the primary waste solution for large medical facilities, health clinics, and hospitals. Its impressive capacity and burn rates make it one of our most sought-after products for substantial medical waste management challenges. 

Features

Unmatched Capacity & Scalability

The i8-M700 offers exceptional waste processing capacity with burn rates up to 300kg per hour, providing the throughput needed for large medical facilities and centralized waste processing operations. Its scalable design allows for future expansion as your waste volumes increase, protecting your investment as organizational needs evolve. 

Superior Performance in Demanding Environments

Developed by a team of highly skilled engineers, our large capacity machines include premium features and intuitive design elements.

Other Features

  • Enhanced Coretex Insulation – Superior thermal efficiency for reduced fuel consumption 
  • Multi-zone Temperature Control – Precise combustion management across chambers 
  • Additional Safety Features – Comprehensive operator protection systems 
  • CE6-VFD Advanced Control Panel – Sophisticated monitoring and operation interface 
  • Hydraulic Doors – Effortless loading of large waste volumes 
  • Top-Loading Design – Superior liquid retention during incineration 
  • Controlled Air Incineration – Optimized combustion for different waste types 
  • High-capacity Combustion Chamber – Accommodates large and bulky waste items 
  • Extended Burn Duration – Capable of continuous operation for high-volume processing 
  • Industrial-grade Refractory Lining – Maximum durability in intensive operation 

Applications

This product can be used in a wide variety of locations and settings. Here are some of the most common places where it is used: 

Facilities that conduct tests on clinical specimens to obtain information about patient health. They perform diagnostic testing, analysis of body fluids, tissues, and other samples to help diagnose, treat, and prevent disease. 

Institutions dedicated to discovering, developing, and testing new medications and therapies. They conduct drug research, clinical trials, and work to advance pharmaceutical treatments for various medical conditions. 

Public health institutions focused on disease prevention, monitoring, and response. They conduct surveillance, research, and provide guidelines to control infectious diseases and other health threats at local, national, or international levels. 

Hospitals with moderate capacity providing comprehensive inpatient and outpatient services. They typically offer emergency care, surgical services, specialised departments, and may serve as regional healthcare hubs for communities. 

Product Specification

Download data sheet
For more detailed information about this incinerator, including technical specifications, download our comprehensive product brochure.
Download

Technical Specifications

Operational Specifications

Combustion Chamber Volume (m3):6.75m3 
Burn Rate*:up to 300kg per hour
Average Fuel Consumption:40 – 50 ltrs p/h
Operational Temperature:> > 850°C
Gas Retention in Secondary Chamber:Up to 2 secs
Temperature Monitoring:Yes
Average ash residue (%):3%
Thermostatic Device:Yes

Physical Specifications

External Length (mm)6040mm
External Width (mm)1910mm
External Height (mm)5750mm
Door Size (mm)4580 x 1500
Shipping Weight15000kg
  

For reference only, not to be used for installation purposes.

* All burn rates are dependant on the calorific value of the waste being incinerate. Atmospheric conditions,fuel (gas/oil) quality, additional accessories (autoloader, de-asher) can also have a major impact on actual burn rates.

Customisation options

Customisation Options

Need product advice? Speak to our specialist sales team.

Speak to an expert

Have any questions? Our experts are ready with answers. Contact us today and discover tailored solutions to your specific challenges. Our team brings years of industry experience to every conversation, ensuring you receive practical advice for your project.

Don’t navigate these decisions alone — click below to contact us.

FAQs

With a burn rate of up to 300kg per hour, the i8-M700 can process approximately 2,400-3,600kg of medical waste in a standard operating day, depending on waste type and operational schedule.

We offer a wide range of support options depending on the level of assistance you require:

  • Our technical support team is available via phone, email and WhatsApp
  • Deployable technical representatives for major installations, training and servicing
  • Web-based troubleshooting and remote diagnostics via video call

The i8-M700 features a high-capacity secondary chamber with 2-second gas retention at temperatures exceeding 850°C, ensuring destruction of harmful compounds. Optional pollution control systems including Venturi scrubbers can be added for enhanced emissions reduction where required by local regulations.

The base unit requires approximately 11.5m² (6040mm x 1910mm) plus appropriate clearances for safety, loading operations, and maintenance access. Additional space may be required for optional equipment such as pollution control systems or automated loading systems.

Routine maintenance includes cleaning chambers, checking filters, and inspecting burners. Inciner8 can help with additional maintenance and training, providing annual servicing, spare parts kits and diagnostics if required.