Incinerator Preventative Maintenance

Request a quote for a preventative maintenance service, today.

Our preventative maintenance service is designed to keep your incinerator operating safely, efficiently and reliably, helping to minimise downtime and extend the working life of your equipment.

Our experienced engineers attend your site to carry out essential inspections, preventative maintenance, component replacements and minor repairs, ensuring key systems are maintained and functioning as intended. Following the visit, you'll receive a detailed service report outlining the work completed, any issues identified and recommendations for further maintenance, helping you keep your incinerator in optimal working condition.

Request a quote

Why preventative maintenance matters

Planned servicing almost always costs less than an emergency repair or a forced shutdown. Regular preventative maintenance protects your investment in several ways:

Less downtime

Catching worn burners, seals and sensors early stops small faults turning into breakdowns that halt your operation.

A longer working life

Routine care of the refractory, burners and controls helps your incinerator reach, and often exceed, its expected service life.

Safer, more efficient operation

Well-maintained combustion and control components keep the incinerator burning cleanly and performing as intended.

Lower running costs

An efficient burn uses less fuel, so a well-tuned machine is a cheaper machine to run.

A clear service history

Documented maintenance supports compliance and makes any future support faster to arrange.

Which incinerators do we service?

We service Inciner8 incinerators of all sizes, from compact clinical units to large industrial and medical waste incinerators. Because we design and build the machines ourselves, our engineers know them inside out, and our global engineer and distributor network means support is rarely far away. If you have inherited an Inciner8 machine or bought one second-hand, we can still help you keep it serviced and supported as part of our aftersales support.

How often should an incinerator be serviced?

As a general guide, an incinerator should have a preventative maintenance service at least once a year. Machines that run daily, handle demanding waste such as clinical or hazardous streams, or operate in harsh environments usually need servicing more often, and often benefit from a planned maintenance schedule rather than a single annual visit. We can recommend the right interval for your model, workload and operating conditions.

Check when your incinerator is due a service

When is your incinerator due a service?

Answer four quick questions for a guide to how often your machine should be serviced.

Please answer all four questions to see your recommended interval.

Recommended service interval

This is a general guide. We can confirm the right interval for your exact model, workload and site conditions.

Request a quote

About your maintenance visit

An Inciner8 engineer will visit your site to carry out the required maintenance work. To ensure the work can be completed safely and effectively, the incinerator must be fully shut down and cooled, with safe access provided, and the necessary utilities and fuel must be available for operational checks.

Scope of works carried out

The table below sets out exactly what a standard preventative maintenance visit covers, so you know precisely what is included before you book.

ItemMaintenance activityWork included
1Visual inspectionInspect accessible incinerator and generator components, chambers, refractory, seals, burners, sensors, controls, cabling and flue. Record visible findings.
2Generator oil changeDrain and replace the generator engine oil, confirm the oil level and check for leakage. The correct oil grade and quantity, and filter if required, must be available.
3Fire-rope inspection and replacementInspect the door fire rope and, where necessary, remove the worn material, clean the channel and install the supplied replacement fire rope and mastic.
4Minor refractory crack sealingSeal accessible minor refractory cracks using the supplied cement repair kit and mastic. Major refractory damage or relining is excluded and will be quoted separately.
5Primary burner replacementRemove the existing primary burner and install the supplied replacement unit. Check connections and test operation where site conditions permit.
6Burner nozzle replacementReplace the two supplied burner nozzles, check seating and connections, and test burner operation where site conditions permit.
7Thermocouple replacementReplace the two supplied thermocouples, verify their connections and confirm that the displayed temperatures respond correctly.
8Photocell replacementReplace the two supplied burner photocells and verify correct flame-detection response during functional testing.

Spare parts supplied with the original system

Each maintenance proposal assumes that the essential spare parts listed below are available on-site, having been supplied as part of the original incinerator purchase. Replacement parts are not included in the maintenance service unless specifically stated in your quotation. To ensure our engineers can complete the required work, all listed items must be available on-site before the scheduled visit or purchased separately as part of your maintenance package.

QuantitySpare part already suppliedIntended maintenance use
1Replacement primary burnerPrimary burner replacement
2ThermocouplesTemperature-sensor replacement
1Cement repair kitMinor refractory crack sealing
1MasticFire-rope and minor sealing work
1Fire ropeReplacement if inspection confirms it is required
2Burner nozzlesBurner nozzle replacement
2PhotocellsBurner flame-sensor replacement

You can order any consumables or replacement parts you are missing through our incinerator spare parts service before the visit.

End-user confirmation required

Before the service visit is confirmed, the end user must verify that every item listed above is available at site in the stated quantity and has been stored correctly, safely and securely in suitable conditions. Parts must be free from visible damage, contamination or deterioration. Any shortage or storage-related concern must be reported to Inciner8 in advance, as it may delay or limit completion of the maintenance scope and require a separate parts quotation.

Functional checks and reporting

Following the maintenance work, the engineer will complete reasonable operational checks permitted by site conditions, including burner operation, thermocouple response, door sealing and observable control functions. Inciner8 will issue a service report recording the work completed, visible findings and any recommended follow-up action.

Please note: This proposal is limited to preventative maintenance and the specific activities stated in the scope of works above. It is not a corrective-repair contract and does not include new spare parts; major refractory repair or relining; repair or replacement of other burners, fans, controls, fuel systems, flues or electrical components; emissions testing; civil works; or lifting and specialist access equipment. Any service beyond this scope, including but not limited to the assessment or repair of serious damage determined to have resulted from misuse by the operator, end user or third parties before, during or after this initial maintenance visit, will require further consultancy and a new quotation. No additional chargeable work will proceed without the customer's prior written approval.

Preventative maintenance FAQs

How much does an incinerator service cost?

Cost depends on your incinerator model, the scope of work required and which parts are needed, so every service is quoted individually rather than sold at a fixed price. Request a quote and our team will put together a scope and price for your machine.

What happens if the engineer finds a bigger problem?

Any issues found are recorded in your service report, along with recommendations. Work outside the agreed preventative maintenance scope, such as major refractory relining or corrective repairs, is quoted separately, and no additional chargeable work goes ahead without your written approval.

Do I need to supply the spare parts?

A standard visit assumes the essential parts supplied with your original incinerator are available on-site. If anything is missing, you can order it from us in advance or add it to your maintenance package, so the engineer can complete the full scope in one visit.

What is the difference between preventative maintenance and a repair?

Preventative maintenance is planned, scheduled work carried out to keep the incinerator running and to catch wear before it causes a fault. A repair is corrective work after something has already failed. This service is preventative maintenance, not a corrective-repair contract.

Can you put us on a regular maintenance schedule?

Yes. For machines in heavy or continuous use, a planned maintenance schedule is usually better value than waiting for problems. Tell us how your incinerator is used and we will recommend a suitable service interval.

Book your incinerator service

Keep your incinerator running safely and avoid unplanned downtime. Request a quote for a preventative maintenance visit and our team will prepare a service scope and price for your machine. For urgent faults between services, our technical support team can help.

Request a quote