I8-M500 Medical Incinerator

I8-M500 model is amongst our largest incinerators.

You get controlled air incineration as standard, providing optimal combustion conditions for different waste types, vital for seasonal and operational variations in your organisation. The over-sized loading door allows bulkier items to be loaded. This design also provides liquid retention making this incinerator ideal for incineration of many different waste streams. Gives you the size, performance and flexibility. Unique value, high quality and total solutions.


I8-M500 Incinerator


Typical Medical Waste Applications


  • Dental / Cosmetic Clinics
  • Blood Banks / Collection
  • Nursing Homes
  • <400 Bed Medical Facilities
  • Medical Waste Collection

All our incinerators are hand-built in the UK by time-served welders and fabricators.

Our award winning design team are always on hand to offer their advice and technical know-how to ensure we get your project off the ground without delay. We can also assist you in the preparation for your planning or permit application where required.


Technical Specs

Operational Specs Physical Specs
Combustion Chamber Volume (m3) 5.00m3 External Length (mm) 4700mm
Burn Rate*
up to 225kg per hour
External Width (mm) 1910mm
Average Fuel Consumption 30 - 40 ltrs p/h External Height (mm) 5750mm
Operational Temperature > 850°C Door Size (mm) mm
Gas Retention in Secondary Chamber 2 secs Shipping Weight 13000kg
Temperature Monitoring Yes    
Average ash residue (%) 3% For reference only, not to be used for installation purposes. * All burn rates are dependant on the calorific value of the waste being incinerate. Atmospheric conditions,fuel (gas/oil) quality, additonal accessories (autoloader, de-asher) can also have a major impact on actual burn rates.
Thermostatic Device Yes
You can also compare our models on our incinerator quick reference page


Click here to view Incinerator Parts.

Accessories & Shipping Options


Configuration Options

On Skid Option Platform Mounted Platform/Skid Mounted
Inciner8 Sheltered Option ShelterPrefabricated Shelter
Inciner8 Containerised Option Containerised Containerised

Optional Extras:

Heat Exchanger Heat Exchanger Heat Exchanger
Venturi Scrubber Venturi Scrubber Venturi Scrubber
Automatic Loading Automatic Loading Automatic Loading
Pollution Control Systems Pollution Control Systems Pollution Control Systems

Spare Parts:

Fuel Tank Fuel tank and piping kit
Electricity Generator Electricity generator