Inciner8

I8-M20 Medical Incinerator

I8-M20 model is an advanced small scale medical incinerator with tertiary air fan and increased insulation to improve performance and provide all-round suitability.

NO Pi8 M20 2

I8-M20 model is an advanced small scale medical incinerator. The i8-M20 is the first in our line of specialist "M" incinerators that are optimised for medical waste disposal.

Overview

The addition of a dedicated advanced control panel allows you to adjust the settings for many different types of medical, clinical, pharmaceutical and hazardous waste streams. This unit also benefits from a secondary chamber with afterburner for the re-burn of harmful emissions with a 2 second retention time.

Features

  • Enhanced Coretex insulation
  • Multi-zone temperature control
  • Mobile options available
  • CE2-VFD Advanced control panel
  • Tertiary air control

Applications

  • Medical Laboratories
  • Dental / Cosmetic Clinics
  • Blood Banks / Collection
  • Nursing Homes
  • < 150 Bed Medical Facilties
  • IMG 20200519 115843
  • IMG 20200519 115635
  • IMG 20200519 115630
  • DSC 0943
  • DSC 0941
  • DSC 0940
Made in britain

Hand-built in the UK

All our incinerators are hand-built in the UK by time-served welders and fabricators. Our award-winning design team are always on hand to offer their advice and technical know-how to ensure we get your project off the ground without delay.

We can also assist you in the preparation for your planning or permit application where required.

Technical specifications

Operational Specifications

Combustion Chamber Volume (m3)
0.18m3
Burn Rate*
up to 20kg per hour
Average Fuel Consumption
7 - 9 ltrs p/h
Operational Temperature
> 850°C
Gas Retention in Secondary Chamber
2 secs
Temperature Monitoring
Yes
Average ash residue (%)
3%
Thermostatic Device
Yes

Physical specifications

External Length (mm)
1070mm
External Width (mm)
660mm
External Height (mm)
4310mm
Door Size (mm)
490 x 490
Shipping Weight
1230kg

For reference only, not to be used for installation purposes. * All burn rates are dependant on the calorific value of the waste being incinerate. Atmospheric conditions,fuel (gas/oil) quality, additonal accessories (autoloader, de-asher) can also have a major impact on actual burn rates.

Optional extras

Sales support

Our friendly and knowledgeable sales team will assist you step by step through the processes, understanding your needs and specifying the optimal solution for your project or waste streams.

+44 (0) 1704 884020

sales@inciner8.com

Technical support

We've invested in our technical support & after-sales so you can now contact us in several ways. Once your request is received, our technical help team will assist with your query.

+44 (0) 1704 884020

support@inciner8.com