You are here:

i8-M100 Medical Incinerator

The i8-M100 is one of our mid-sized models that can be used for a variety of medical applications. Large enough to offer impressive burn rates and batch sizes, while still small enough to fit all our mobile options.

The i8-M100 features a top-loading design with a large opening for bulky waste. The i8-M100 benefits from a secondary chamber with an afterburner for the re-burn of harmful emissions with a 2 second retention time.

Features

Large loading door

Designed specifically for medical waste with a large loading door (1450 x 750mm) for bulky items, ensuring maximum operational flexibility.

Designed for medical waste management

Enhanced performance through advanced controls and improved insulation, creating optimal combustion conditions for various medical, clinical, pharmaceutical, and hazardous waste streams.

Other Features

  • Dual-Chamber Technology – Ensures complete combustion while meeting environmental regulations. 
  • Intuitive Control Panel – Allows independent adjustment of temperature and burn time for efficient operation. 
  • Top-Loading Design – Large loading door for a simple and convenient waste loading system.
  • Automatic Safety Shutoff – Protects operators by deactivating the primary chamber burner when the lid is open. 
  • Ash Removal Door – Allows safe and easy removal of ash after combustion. 
  • Modular Pollution Control Systems – Optional additions, such as scrubbers, reduce emissions further. 
  • Durable Stainless-Steel Flue – Ensures efficient exhaust gas removal and long service life. 

Applications

This product can be used in a wide variety of locations and settings. Here are some of the most common places where it is used: 

This is a block of placeholder text which is being used to fill the white space on this page and demonstrate what the text styles will look like once the real content has been provided.

There are certain paragraph styles which we need to test to ensure they look right, such as italics, bold text, underlined text, highlighted text, and abbr.
Until we have the final content provided, we need to use this dummy text to ensure a smooth transition when real text is added.

Here is an example of a hyperlink, which should be styled distinctively.
This ensures visitors can clearly identify links within the content.

Facilities that conduct tests on clinical specimens to obtain information about patient health. They perform diagnostic testing, analysis of body fluids, tissues, and other samples to help diagnose, treat, and prevent disease. 

Public health institutions focused on disease prevention, monitoring, and response. They conduct surveillance, research, and provide guidelines to control infectious diseases and other health threats at local, national, or international levels. 

Comprehensive facilities serving broader geographic areas, often acting as hubs for specialised care. They provide a wide range of medical services, specialty clinics, and may coordinate healthcare delivery across multiple communities. 

Product Specification

Download data sheet
For more detailed information about this incinerator, including technical specifications, download our comprehensive product brochure.
Download

Technical Specifications

Operational Specifications

Combustion Chamber Volume (m3):1.35m3 
Burn Rate*:up to 80kg per hour
Average Fuel Consumption:14 – 19 ltrs p/h
Operational Temperature:> > 850°C
Gas Retention in Secondary Chamber:Up to 2 secs
Temperature Monitoring:Yes
Average ash residue (%):3%
Thermostatic Device:Yes

Physical Specifications

External Length (mm)2540mm
External Width (mm)1100mm
External Height (mm)4180mm
Door Size (mm)1450 x 750
Shipping Weight3100kg
  

For reference only, not to be used for installation purposes.

* All burn rates are dependant on the calorific value of the waste being incinerate. Atmospheric conditions,fuel (gas/oil) quality, additional accessories (autoloader, de-asher) can also have a major impact on actual burn rates.

Customisation options

Customisation

Need product advice? Speak to our specialist sales team.

Speak to an expert

Have any questions? Our experts are ready with answers. Contact us today and discover tailored solutions to your specific challenges. Our team brings years of industry experience to every conversation, ensuring you receive practical advice for your project.

Don’t navigate these decisions alone — click below to contact us.

FAQs

Our advanced secondary chamber technology with a gas retention time of up to 2.0 seconds allows our incinerators to comply with environmental standards while processing volumes of waste. Additional pollution control systems such as a venturi wet scrubbers, can be added for volatile or hazardous waste.

Routine maintenance includes cleaning chambers, checking filters, and inspecting burners. Inciner8 can help with additional maintenance and training, providing annual servicing, spare parts kits and diagnostics if required.

Our award-winning engineering team is always on hand to offer advice and technical know-how to ensure projects get off the ground without delay. We can also assist with installation, maintenance and training.

We offer a wide range of support options depending on the level of assistance you require:
  • Our technical support team is available via phone, email and WhatsApp
  • Deployable technical representatives for major installations, training and servicing
  • Web-based troubleshooting and remote diagnostics via video call
The complete range of Inciner8 incinerators are shippable to any sea-port in the world. A variety of additional mobile options are available to enable rapid development and simple installation.