I8-1000 General Incinerator

Summary

The I8-1000 model is our largest incinerator giving you high volume capacity for your waste needs. This model is a controlled air incinerator, providing optimal combustion conditions for different waste types. Featuring our SMARTPANEL technology, this system can learn about your waste stream, then via remote diagnosis we can fine tune its performance to suit your needs. Available with a wide range of pre-combustion modules to improve throughput and comprehensive options for the handling of exhaust gases. Professionally installed and maintained if you sign up for our Inciner8 Network services.

 

Emission Data

Average emissions / EU standards On basic incinerators (with secondary chamber)

Parameter Limits
(1/2 hr av)
Measured
Total dust 30 mg/m3 12 mg/m3
Sulphur dioxide 200 mg/m3 2,4 mg/m3
Nitrogen dioxide* 400 mg/m3 60 mg/m3
Carbon monoxide 100 mg/m3 78,3 mg/m3

For more information on how our I8-1000 Incinerators can help you with General waste

Call us now on +44 (0)1704 884020 or use the Contact Us page.

Typical General Waste Applications

  • Remote Housing
  • Bigger Camps
  • < 5000 People Comunities
  • Industrial Waste < 8000kg day
  • Universities

All our incinerators are hand-built in the UK by time-served welders and fabricators. Our award winning design team are always on hand to offer their advice and technical know-how to ensure we get your project off the ground without delay. We can also assist you in the prerparation for your planning or permit application where required.

Technical Specs

Operational Specs Physical Specs
Combustion Chamber Volume (m3) 8.72m3 External Length (mm) 6490mm
Burn Rate*
up to 1000kg per hour
External Width (mm) 2000mm
Average Fuel Consumption 65 kg per hour External Height (mm) 6260mm
Operational Temperature 850 - 1300°C Shipping Weight 21500kg
Gas Retention in Secondary Chamber 2 secs    
Temperature Monitoring Yes    
Average ash residue (%) 3%    
Thermostatic Device Yes    
*Subject to calorific value of waste stream. For reference only, not to be used for installation purposes.

Options

On Skid Option Platform Mounted

Platform Mounted

Inciner8 Containerised Option Containerised

Containerised

Extras:

Inciner8 Heat Recovery Heat Exchanger

Heat Exchanger

Venturi Scrubber Venturi Scrubber

Venturi Scrubber

Pollution Control Systems Pollution Control Systems

Pollution Control Systems

Parts:

Fire rope, Refractory kit, Mastic, Burner, Thermocouple 1 year spare parts package
Fuel Tank Fuel tank and piping kit
Electricity Generator Electricity generator